PM series balances are equipped with an innovative measuring system based on RADWAG MonoBLOCK® technology.
Use of the new measuring system, which is a subject matter of RADWAG patent, guarantees stability of repeatability over time at a range sd < 1d. The unique measuring system solution is characterized with great resistance to ambient conditions change.
An in-built 4-point protection system prevents balance overloading, this ensures safety in case too heavy load is applied onto the weighing pan.
Main features:
- new RADWAG MonoBLOCK® sensor
- unrivalled repeatability of indications
- weighing of heavy loads with maximum accuracy
- intuitive operation guaranteed by a membrane keyboard
- fast mass measurements
- robust mechanical design – new lower weighing platform
- improved ergonomics – two types of weighing terminal for selection.
Balance offers possibility of weighing loads outside the weighing platform (so called under-pan weighing). This is an alternative for weighing loads with non-standard dimensions and shapes or those generating magnetic field.
Specification | WL-223-0005 (PM 10.C32) | WL-223-0006 (PM 15.C32) | WL-223-0007 (PM 35.C32) |
Maximum capacity [Max] | 10 kg | 15 kg | 35 kg |
Preload | 1 kg | 1.5 kg | 3.5 kg |
Minimum load | 0.5 g | 0.5 g | 5 g |
Readability [d] | 0.01 g | 0.01 g | 0.1 g |
Verification scale interval [e] | 0.1 g | – | 1 g |
Tare range | -10 kg | -15 kg | -35 kg |
Repeatability (5% Max) * | 0.004 g | 0.004 g | 0.04 g |
Repeatability (Max) * | 0.01 g | 0.015 g | 0.1 g |
Linearity | ± 0,03 g | ± 0,03 g | ± 0,3 g |
Sensitivity temperature drift ** | 2 × 106 / °C × Rt | 2 × 106 / °C × Rt | 2 × 106 / °C × Rt |
Minimum weight (U = 1%, k = 2) | 0.82 g | 0.82 g | 8.2 g |
Minimum Heavy (USP) | 8.2 g | 8.2 g | 82 g |
Stabilization time | 3 s | 3 s | 3 s |
Adjustment | internal | internal | internal |
Verification | Yes | – | Yes |
OIML accuracy class | II | – | II |
Indicator fastening | 1.5 m cable | 1.5 m cable | 1.5 m cable |
Terminal model | PUE C32 indicator | PUE C32 indicator | PUE C32 indicator |
Display | 5” graphic colour | 5” graphic colour | 5” graphic colour |
Keypad | 22-key membrane | 22-key membrane | 22-key membrane |
Protection class | IP 43 | IP 43 | IP 43 |
Databses | 5 | 5 | 5 |
Touch-free operation | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors |
USB-A | 1 | 1 | 1 |
USB-B | 1 | 1 | 1 |
RS 232 | 2 | 2 | 2 |
Ethernet | 10 / 100 MBit | 10 / 100 MBit | 10 / 100 MBit |
Wi-Fi® | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n |
Power supply | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC |
Power consumption | 15 W | 15 W | 15 W |
Operating temperature | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C |
Atmospheric humidity*** | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% |
Transport and storage temperature | –10 ÷ +50 °C | –10 ÷ +50 °C | –10 ÷ +50 °C |
Weighing pan dimensions | 200 × 185 mm | 200 × 185 mm | 347 × 259 mm |
Weighing pan material | aluminum EN AW-7075 | aluminum EN AW-7075 | stainless steel 0H18N9 |
Weighing device dimensions | 508 × 296 × 115 mm | 508 × 296 × 115 mm | 508 × 296 × 115 mm |
Net weight | 10 kg | 10 kg | 11 kg |
Gross weight | 12.2 kg | 12.2 kg | 13.2 kg |
Packing dimensions | 520 × 520 × 280 mm | 520 × 520 × 280 mm | 520 × 520 × 280 mm |
Specification | WL-223-0008 (PM 50.C32) | WL-223-0009 (PM 60.05.C32) | WL-223-0012 (PM 60.1.C32) |
Maximum capacity [Max] | 50 kg | 60 kg | 60 kg |
Preload | 5 kg | – | – |
Minimum load | 5 g | 0.5 g | 1 g |
Readability [d] | 0.1 g | 0.5 g | 1 g |
Verification scale interval [e] | 1 g | – | – |
Tare range | -50 kg | -60 kg | -60 kg |
Repeatability (5% Max) * | 0.04 g | 0.2 g | 0.4 g |
Repeatability (Max) * | 0.15 g | 0.4 g | 0.8 g |
Linearity | ± 0,3 g | ± 1,5 g | ± 3 g |
Sensitivity temperature drift ** | 2 × 106 / °C × Rt | 2 × 106 / °C × Rt | 2 × 106 / °C × Rt |
Minimum weight (U = 1%, k = 2) | 8.2 g | 41 g | 82 g |
Minimum Heavy (USP) | 82 g | 410 g | 820 g |
Stabilization time | 3 s | 3 s | 3 s |
Adjustment | internal | internal | internal |
Verification | Yes | – | – |
OIML accuracy class | II | – | – |
Indicator fastening | 1.5 m cable | 1.5 m cable | 1.5 m cable |
Terminal model | PUE C32 indicator | PUE C32 indicator | PUE C32 indicator |
Display | 5” graphic colour | 5” graphic colour | 5” graphic colour |
Keypad | 22-key membrane | 22-key membrane | 22-key membrane |
Protection class | IP 43 | IP 43 | IP 43 |
Databses | 5 | 5 | 5 |
Touch-free operation | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors |
USB-A | 1 | 1 | 1 |
USB-B | 1 | 1 | 1 |
RS 232 | 2 | 2 | 2 |
Ethernet | 10 / 100 MBit | 10 / 100 MBit | 10 / 100 MBit |
Wi-Fi® | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n |
Power supply | 13.5 ÷ 16 V DC | 13.5 ÷ 16 V DC | 13.5 ÷ 16 V DC |
Power consumption | 15 W | 15 W | 15 W |
Operating temperature | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C |
Atmospheric humidity*** | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% |
Transport and storage temperature | –10 ÷ +50 °C | –10 ÷ +50 °C | –10 ÷ +50 °C |
Weighing pan dimensions | 347 × 260 mm | 500 × 400 mm | 500 × 400 mm |
Weighing device dimensions | 508 × 296 × 115 mm | 640 × 400 × 115 mm | 640 × 400 × 115 mm |
Net weight | 11 kg | 17 kg | 17 kg |
Gross weight | 13.2 kg | 19 kg | 19 kg |
Packing dimensions | 520 × 520 × 280 mm | 700 × 600 × 200 mm | 700 × 600 × 200 mm |