Highly practical standard ovens with maximum temperature up to 300°C.
Features of Forced Convection Oven (DKN602)
Standard forced air convection ovens
Standard forced air convection ovens are programmable and come with extended functions and safety features.
Feature
Best seller based on excellent performance & affordability
Feature
Superior temperature accuracy
Feature
DKN302/402/602/612 come with observation windows
Feature
Programmable PID controller for easy program settings 30-step, 3-pattern program controller with repeat functions
Feature
Fixed setting, programmed, Quick Auto stop, Auto stop, and Auto start operating modes with easy control capabilities
Feature
Increased safety and Self-diagnostic function
Feature
Over-heating prevention and calibration off-set are possible with auxiliary functions
Feature
Easy to use and maintain
Feature
Built in exhaust ports
Safety features
Self diagnosis functions (Temperature sensor abnormal, Heater disconnection, SSR-short) Automatic overheating prevention, Electric leakage breaker with over current protection, Key lock function
Specifications | ||
Item Code | 212872 | |
Model | DKN602 | |
Circulation method | Forced air circulation | |
Operating temp. range | Room temp. +10°C to 250°C | |
Temp. adjustment accuracy | ±1℃(at 210℃) | |
Temp. distribution accuracy | ±2.5℃(at 210℃) | |
Max. temp. reaching time | Approx. 120 min | |
Interior/Exterior material | Stainless steel / Cold rolled steel plate with melamine resin baking finish | |
Heat insulating material | Glass wool | |
Heater | 1.34 kW | |
Fan Type / Fan Motor | Scirocco fan, Condenser type motor | |
Cable hole | 30mm I.D. (on the right side) 1pc. | |
Exhaust port | 30 mm l.D.×2 pcs.(on top) | |
Observation window | 250×280mm Chemical strengthening glass x 3 | |
Temp. controller | PID control by microprocessor | |
Temp. setting method | Digital setting by UP/DOWN key | |
Temp. display | Measurement temp. : Digital display by green LED Setting temp. : Digital display by red LED | |
Timer | 1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50 min. with timer wait function | |
Operation function | Fixed temperature operation, Program operation, Auto start, Quick Auto-stop | |
Program mode | Program operation : 30 steps (30 steps×1, 15 steps×2, 10 steps×3) Pattern repeat function | |
Additional functions | Calibration off-set function, Key lock, Uninterruptible power for memory | |
Heater circuit control | SSR control | |
Sensor | K-thermocouple | |
Safety device | Self diagnosis functions (temp. sensor abnormal, Heater disconnection, SSR- short, Automatic overheating prevention), Key lock function, Overheat prevention, Electric leakage breaker with over current protection | |
Shelf plate with standard load | ~15kg/piece | |
Shelf support step number/pitch | 13 steps / 30mm | |
Shelf plate | Stainless steel, 1pc on the bottom screwed | |
Shelf plate / support | 2 pcs. / 4 pcs. | |
Internal dimensions(W×D×H mm) | 600×500×500mm | |
External dimensions(W×D×H mm) | 710×651×870mm | |
Remarks(dimensions) | 150L | |
Power Source | AC115V 13A Single-phase |
|
Weight | 65kg |